Wall switch off the ground should be www.facebook.com/guohong.trading 1.3 meters, 0.3 mira line wall socket switch should be 2-3 m above the floor. Electricity meter from the ground should be 1.4-1.8 meters into the line the ground should be 2.7 meters from the diesel engine path, a, secondary roads, electric drive, the main river, low voltage circuit, special cableway, etc, should not have joint. Ming with plastic sheath line is mainly used for indoor installation, may not be directly into the plaster layer in the dark with laying. Wire wear tube general requirements tube total cross- sectional area of the wire (including insulation) is not more than 40% of electric water pump line pipe inner sectional area. Wire tube shall have joint, joint should be within the junction box; Different power supply circuit and voltage loop, as spare circuit, line work lighting 3 phase induction motor and emergency lighting shall be installed in the same tube. Pipe for steel pipe (tube), the same communication circuit wiring must wear the same tube, do not allow a wire through a steel tube. 


CCC CE ROHS UL VDE Certification and 115/120 V AC Voltage 220V&120V induction motor

Specifications
1. Specifications1.3-phase asynchronous motors 
2. IEC standard 
3. OEM 
4. Voltage:50HZ &60HZ;380V&415V 

5.Protection class: IP54 
A root canal on the conductor shall not exceed small diesel engine eight. Steel (iron) for pipe, the pipe must be reliable grounding. Pipe for steel pipe (tube), the line must add plastic on alternator generator both ends of pipe. Wire wear tube length of more than 30 meters (half hard tube) which should be installed between the junction box. Wire wear tube length more than 40 meters (iron pipe) which should be installed between the junction box. single phase induction motor Wire wear tube, there is a curved line pipe length no more than 20 meters. Which should be installed between the junction box. Wire wear tube, there are two curved line pipe length is not more than 15 meters. Which should be installed between the junction box. Wire wear tube, there are three bending tube length is not more than 8 meters. Which should be www.dongfeng- motor.com installed between the junction box. When using polyphase power supply, wire of the same building insulation color selection should be consistent, namely protect wire (PE) should be green/yellow double-color wire, neutral wire (N) line for the light blue; Line L1 - yellow, L2 - green, L3 - red. Single-phase power supply switch line is red, after the switch general USES white or yellow. magnetic generator Joint position of the wire should not be in the insulator fixed place, joint location away from the wires should be above 0.5 meters, hampering binding wire and broken.

没有评论:

发表评论