显示标签为“rotor balancing machine”的博文。显示所有博文
显示标签为“rotor balancing machine”的博文。显示所有博文

2014年10月9日星期四

Dc voltage measurement


This is a current situation,the multimeter dc voltage in the dc power supply voltage,measure the working voltage of peripheral components;Different IC pins of dc voltage value,and compared with the normal,and compression failure,find out the damaged components.When measured at 8 o 'clock to pay attention to the following:(1) the multimeter to want to have enough resistance,at least more than 10 times greater than the resistance of the circuit being measured,so as not to cause greater error of measurement.(2) usually put the potentiometer to the middle position,if it is a TV set,signal source to adopt standard color bar signal generator.(3) to take pens and asynchronous motor or probe anti-skid measures.For any instantaneous short circuit is easy to damage the IC.Can take the following methods to prevent the pens and sliding: take a bike with a valve core set of pen in the table,and the long table pen is about 0.5 mm or so,it can make the table pen well and the point contact under test,and motor run capacitor can effectively prevent the skid,and even meet with neighboring points can not short circuit.


(4) when the measured voltage does not accord with normal,a pin voltage should be based on the pin to IC normal work have important influence as well as the other pin voltage were analyzed,and the corresponding change to ac electric motor judge of IC.(5) IC pin voltage will be affected by peripheral components.As peripheral components occurs leakage,short circuit,open circuit or value,or peripheral circuit connection is a variable resistance value of the potentiometer,the location of the potentiometer arm,will make the change pin voltage.(6) if IC voltage is normal,the pin is thought IC is normal;If abnormal voltage IC part pin,it should maximize deviation from normal,check the peripheral components for XXX,if wholesalemotor.blogspot.com no failure,the IC is likely to be damaged.(7) for dynamic receivers,such as TV,in the presence of signal,IC pin voltage is different.If discover pin voltage should not change but change is big,the size and adjustable with the signal components of different locations and change but do not change,can determine the damage of the IC.(8) for a variety of ways of working device,such as video,work in a different way,each pin voltage IC are also different.

2014年10月8日星期三

Multimeter application technique measure skills


1,the road test diode,transistor,voltage regulator tube is good or bad,because in the actual circuit,bias resistors or diode triode,voltage regulator tube peripheral resistance is compared commonly big,mostly over hundreds of thousands of ohm,in this way,we can use the multimeter R * 10 Ω or R electricalmotor1.blogspot.com 1 Ω shift to measure the p-n junction of the road. In road measurement,measurement in R x 10 Ω gears p-n junction should have a clear direction,features (if the positive and negative to the resistance differs not quite apparent,can convert R x 1 Ω file to test),generally positive resistance at R x 10 Ω file whose hands should be instructed in about 200 Ω,time measurement motor run capacitor in R x 1 Ω file whose hands should be indicated when measuring around 30 Ω (according to different phenotypes may differ ac electric motor slightly). 

Forward resistance is too big or reverse measurement results if the value is too small,suggests that the p-n junction has a problem,the tube also have a problem. This method was especially effective for maintenance,can very quickly find out bad tube,even has not been fully broken can be detected but bad tubes. For example,when you use small resistance profile measurement is a PN junction resistance is ac induction motor too large,if you put it down with the commonly used welding Ω R x 1 k file and test,may be normal,in fact,the characteristics of the tube has gone bad,cannot work normally or unstable.2,measuring resistance: it is important to choose the right range,when the pointer instructions from 1/3 to 2/3 full scale measurement precision is highest,the most accurate. Note that in R x 10 k ohms resistance measured level of resistance values,not to fingers on both ends of the resistance,so that the body resistance will make small measurement results.

2014年9月11日星期四

Low voltage circuit breaker C45 series


C45 series is the introduction of merlin gerin (France) technology products,domestic models for DZ47.As the light distribution system,motor power distribution system and electrical control circuit overload protection and short circuit protection.3.The main technical parameters of low-voltage circuit breaker: 1) refers to the circuit breaker rated voltage under prescribed conditions for long-term running can withstand voltage,generally for the line voltage.Commonly used with ac 220 v,380 v,500 v,660 v,etc.2) rated current refers to the circuit breaker can be long-term wholesalemotor.blogspot.com under prescribed conditions by the current,rated current is known as the trip.

3) the rated short circuit making capacity Refers to the circuit breaker under the condition of single phase electric motorrated frequency and power factor and other rules,the ability to turn on the short
circuit current,with the maximum peak current said.4) rated short circuit breaking capacity Refers to
the circuit breaker and the rated frequency under specified conditions,such as power factor,to
breaking the maximum short-circuit current value.5) rated short-time resistance current Refers to the
circuit breaker under specified test conditions,can withstand current value within a specified
Dongfeng Electric between timely.From the action time of the 6):refers to the electrical control line began to contact separation,short circuit instantaneous arc extinguishing,circuit completely breaking all need time,also known as gasoline generator the breaking time,generally is 30 ~ 60 ms.

The operation of the three-phase asynchronous motor monitoring


Three-phase asynchronous motor running monitoring:1,monitoring,motor overheating 2,monitoring the working current of the motor is more than the rated current 3,monitor power supply voltage with or without changes 4,monitor whether the three-phase power supply voltage and current balance Note: in the operation of the three-phase asynchronous motor 1,pay attention to the ventilation of the motor and the environment 2,pay attention to the motor vibration 3,pay attention to the noise of the motor with or without abnormal situation 4,pay attention to whether motor abnormal smells 5,pay attention to the working condition and fever motor bearing Daily monitoring master electrician motor five often:1,often listen to.Motor issue during normal working uniform "buzzing" sound.Particularly heavy when I heard the "buzzing" sound,or "utter the word" sound,motor open phase running.

If heard a continuous "guru" or "giggle" sound,that there is something wrong with the motor bearings 2,often
have a look.See the ammeter or a voltmeter indicates whether or not the normal;See if three phase
current balance;See whether the power supply voltage of three-phase;See Motor
vehicle if motor on the basis of solid,etc.3,often monitoring environment temperature.The output power of the motor temperature has a great relationship with the surrounding environment,the
environment temperature is higher,the smaller the motor output power.When the environment temperature below 35 ℃,motor power output will be greater than the rated power output,the increase of amplitude of (35) % (t for the actual environment temperature),but not more than 8% - 10%;When the environment temperature above 35 ℃,the output power of the motor than rated output power reduction (t - 35) %.4,often feel.Back with your fingers touch the motor shell,temperature rise is too high.As the hot
hand,motor has overheating.5,often smell.Whether with his nose close to the motor,smell the smell of
insulating varnish or anxious burnt flavour.If have,diesel generating set could be the result of a coil of motor overheating and short circuit,etc.

2014年8月13日星期三

Three-phase asynchronous motor rotor current and the stator current is increased or decreased?

Three-phase asynchronous motor in the power supply voltage must be,if the load resistance increases,will force the output of the electricalmotor1.blogspot.com motor torque increase,at this point,the rotor of the motor current and stator current how will increase
accordingly.Three-phase asynchronous motor in the power supply voltage must be,if the load resistance increases,will force the output of the motor torque increase,at this point,the rotor of the motor current and stator current how will increase accordingly.Three-phase three phase generator asynchronous motor running under the rated voltage,load increases,the resistance torque is increased,the speed will be reduced,but very small,so that the motor stator and rotor of frequency offset,the impedance of the system (inductance),three phase stator current,rotor induced current also increases accordingly.Of course the load increases load power is also increased.By reducing load increase,rotational motor fan speed,the motor rotor speed than the stator rotating magnetic field rotation speed increase.Slip,motor output torque increase,at a certain frequency and voltage.The rotor and stator of the motor current will increase.Current increase natural motor output power is bigger.

Rapid detection of the three-phase asynchronous motor winding judgment method

Rapid detection of the three-phase asynchronous motor winding judgment method,1,balance of the three-phase winding resistance.The multimeter R x 1 Ω resistance,which leads to the cable resistance value of the (3),should be equal.Such as,cable or motor winding fault;Should further wholesalemotor.blogspot.com measurement on the junction pole of the motor,such as ranging,explain the motor winding is defective.2,ground check.The multimeter R x 10 k or R x 1 k resistance measurement cable core screw together (3) and the casing,the resistance value between the www.facebook.com/guohong.trading less than 0.5 M Ω,be affected with damp be
affected with damp;Close to zero,is probably the ground fault.3,check insulation between the phase
within.Can be connected patches on the terminal small electric motors will be
removed,polished terminal resistance perkins diesel generator value between the above three terminal,less than 0.5 M Ω,be affected with damp be affected with damp;Close to zero,is likely to be short circuit fault.4,the rotor can check.In the case of without load,with the hand gently turn the motor shaft,such as transfer,illustrate bearing failure.

2014年6月23日星期一

220V YC single-phase asynchronous electric motors double running capacitors IP44 IP55 IP56 1.2.3.4.5hp high torque


Varieties of Linear Actuator suitable to receive business oriented programsLinear actuator
most likely preferred equipments when it is about. The device's build and stability definitely
typically has always been revolutionary. While using several materials and moreover items
composing ship catalyst is no issue. Be cable hands free operation may well formed up
utilizing primary pieces. Advance of outdoor energy levels is vital regarding that drive to
plan the outcome. The effectiveness of some mobile phones are described by using identifiable
supplies.There are varieties of linear actuator available for sale that can cause used
according to your wants, Around the internet expenditure belongs to the preferred solutions
which they can use. Running a process can be accomplished by using types of actuators which
www.dongfeng-motor.com were created for more ac motor partscostly professional use.

Gas actuators offered that's good for you if you use essential body essential liquids. Gas
fluid happens to be moved in a ppoleton and this also operates range of move. They have
already gas cylinders what type projects good whenever a a would ought lower motions. The
particular closes from your piston are hands down under time limits pursuant to upmost
requirements; They even distribute correct based on the pressure derived. Pneumatically-driven
options can be favored to carry massively popular congestion constructed from electrical motor many different professional software pacakages. Having access to gas linear actuator is designed in different
times when a contact huge demand for harmony. Control over sorts instruments is nerely
fantastic and enormus. Expense of really aids may be within the box in addition developed from
new hi-tech.